Operation GP/GPS 6600A
32
5.16 Voltage Selection
See Graphic: wc_gr002497
The voltage selector switch (e) allows the generator to operate in either
single (120V) or dual voltage (120/240V) mode.
In single-voltage mode, use only the 120V twist-lock (c) and duplex
receptacles (f1, f2). The full rated power of the generator is shared
between the three receptacles.
In dual voltage mode both the 120V and 120/240V receptacles are
powered; lower watts are available on receptacles (f1, f2, c). The 120/
240V twist-lock receptacle (j) should be used in dual mode only. To
achieve full power in this receptacle it should be used alone.
NOTICE: NEVER switch the voltage selector switch with the main
breaker on! This can cause arcing and can damage the generator.
Turn all tools and appliances off and place main breaker (d) in the OFF
position before changing voltage switch position.