Wacker Neuson WL 30 Instrukcja Operatora Strona 28

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 246
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 27
B A S I C S A F E T Y I N S T R U C T I O N S
26
WARNING
Electric shock hazard.
The operator of the Wheel Loader can be killed if
the Wheel Loader comes in contact with electrical
wires.
Keep the loader and attachment tools at a suf-
cient distance from overhead power lines and
other electrical lines of more than 50 V (see
table below).
If inadvertent contact with a live electric source occurs:
Do not leave the loader until the electricity has been
disconnected and a qualied technician directs the op-
erator to leave the machine..
If feasible, drive the loader away from the danger area!
Warn any people around the loader not to get any nearer
and not to touch the machine.
Arrange to have the power turned off.
2.4.2 Working near overhead power lines
Nominal voltage Clearance distance
up to 1000 V 1 m 3.3 ft
over 1 kV up to 110 kV 3 m 9.8 ft
over 110 kV up to 220 kV 4 m 13 ft
over 220 kV up to 380 kV 5 m 16.4 ft
Unknown nominal voltage 5 m 16.4 ft
Przeglądanie stron 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 245 246

Komentarze do niniejszej Instrukcji

Николай 26 Nov 2024 | 09:45:32

Назначение плавких предохранителей