Wacker Neuson WL 30 Instrukcja Operatora Strona 151

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 246
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 150
S E R V I C I N G A N D I N S P E C TI O N
149
W L 3 0
Work to be performed
Operating hours:
250, 750, 1000,
1250, 1750,
2000, 2250,
2750, 3000, etc.
Operating
hours: 1500,
2500, 3500,
4500, etc.
monthly annually
Check all the oil levels X X
Check according to the Ordinance on Industrial Safety and Health X X
* Required if there is a damage in the hydraulic system which is supposed to be caused by strong abrasive wear
Valve clearance for Perkins 400 series: 0.2 mm (0.008”) inlet and outlet for a cold engine
Valve clearance for Perkins 1000 series: 0.2 mm (0.008”) inlet and 0.45 mm (0.04”) outlet for a cold engine
Valve clearance for Deutz 2011 series: 0.3 mm (0.012”) inlet and 0.5 mm (0.04”) outlet for a cold engine
Przeglądanie stron 150
1 2 ... 146 147 148 149 150 151 152 153 154 155 156 ... 245 246

Komentarze do niniejszej Instrukcji

Николай 26 Nov 2024 | 09:45:32

Назначение плавких предохранителей