Cub 200/300/300 HD Maintenance
wcghi_tx000721gb.fm 33
4.6 Inspecting and Cleaning the Cadmium (CAD) Cell
See Graphic: wcghi_gr004021
To inspect and clean the CAD cell, carry out the following procedure.
4.6.1 Remove the burner assembly. See section Removing and Installing
the Burner Assembly.
4.6.2 Twist and pull out the plastic protective holder (1) off the base of the
burner assembly. The CAD cell is inside this plastic holder.
4.6.3 Inspect the CAD cell for the following:
Cleanliness. Be sure the cell is free of debris or soot.
4.6.4 Clean the cell if necessary.
NOTICE: Do NOT use solvents or liquids to clean the CAD cell. Use a
soft dry cloth to clean the CAD cell.
4.6.5 Reinstall the plastic protective holder (1) onto the base of the burner
assembly.
4.6.6 Reinstall the burner assembly. See section Removing and Installing
the Burner Assembly.