Maintenance GP 4000
40
3.11 Electrical Schematic (CAN models only)
Ref. Description Ref. Description
A Generator D Wacker Neuson Engine
B Control box
Ref. Description Ref. Description
1 Main stator winding 1 13 Rectifier
2 Main stator winding 2 14 Rotor winding/brushes
3 Auto idle unit 15 Secondary (excitation) winding
4 Main circuit breaker 16 DC winding
5 Voltage selector switch
(120/240V position shown)
17 Automatic voltage regulator (AVR)
6 Duplex receptacle—120V 20 GFCI
7 Twist-lock receptacle—120V 21 20A circuit breaker
8 Twist-lock receptacle—120/240V 22 20A circuit breaker
(GP 3800 CAN and GP4000 only)
9 Auto idle switch 23 30A circuit breaker
(GP 5600/6600 CAN only)
10 5A fuse 24 Neutral bond wire
12 Engine ON / OFF switch