Strona 2

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL V. 2, Rev. 09/01/06 vi © 2006 Ground Heaters, Inc. TABLE OF CONTENTS (continued) Page MAIN

Strona 3 - One Year Limited Warranty

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’SMANUAL © 2006 Ground Heaters, Inc. vii V. 2, Rev. 09/01/06 TABLE OF CONTENTS

Strona 4

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL V. 2, Rev. 09/01/06 viii © 2006 Ground Heaters, Inc. TABLE OF CONTENTS (continued) Page APPE

Strona 5 - i V. 2, Rev. 09/01/06

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL SPECIFICATIONS V. 2, Rev. 09/01/06 ix © 2006 Ground Heaters, Inc. SPECIFICATIONS

Strona 6 - WARNING

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL V. 2, Rev. 09/01/06 x © 2006 Ground Heaters, Inc. LIST OF ABBREVIATIONS The following is a list

Strona 7 - Appellez le 877-799-9600

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 1 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 1- 1 INTRODUCTION The Pureheat™ Hydr

Strona 8 - INTRODUCTION

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 1 1- 2 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 1.1 EXTERNAL FEATURES (Ph

Strona 9

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 1 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 1- 3 1-2 1 2 3 9 10 11 16 5 6 7 4 8 14

Strona 10

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 1 1- 4 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 1-3 1 6 2 3 4 5 8 1-4 1

Strona 11 - APPENDIX A

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 1 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 1- 5 1.2.3 Inside Rear Doors The foll

Strona 13 - SPECIFICATIONS

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 1 1- 6 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 1.3 IDENTIFICATION The

Strona 14 - LIST OF ABBREVIATIONS

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 1 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 1- 7 1.5.1 Burner Setup, Installation

Strona 15 - (4) 100 ft. (30 m )

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 1 1- 8 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 9. Do not transport peop

Strona 16

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL–SECTION 2 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 2- 1 START UP, OPERATION AND SHUTDOWN

Strona 17

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 2 2- 2 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 2.1.1.5 HX50 Heat Xchangers

Strona 18

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL–SECTION 2 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 2- 3 2.1.4 Insulate Circulation Hoses

Strona 19

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 2 2- 4 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 2-42-3 2.2.3 Unloading HX10

Strona 20

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL–SECTION 2 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 2- 5 2-5 Valve #2 2-6 Valve #1 Valve #

Strona 21

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 2 2- 6 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 2-7 2-8 2.4.2 Warming the He

Strona 22 - ™ Hydronic Air Heater

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL–SECTION 2 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 2- 7 2.5 OPERATING WITH OPTIONAL ACCE

Strona 23

One Year Limited Warranty (see your distributor to file warranty claim) Ground Heaters, Inc. warrants that the Products described in this Limited War

Strona 24

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 2 2- 8 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 2. Place the Five (5) HHS30

Strona 25

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL–SECTION 2 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 2- 9 2-12HX200 HX100 HX50 Support Bar

Strona 26

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 2 2- 10 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 2-13Valve #7 Valve #5 Valve

Strona 27

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL–SECTION 2 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 2- 11 11. Connect a heavy duty 10-3

Strona 28

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 3 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 3- 1 BURNER ADJUSTMENT AND SHUTDOWN

Strona 29

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 3 3- 2 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 3.1.1.1 Fuel Pressure Adjus

Strona 30

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 3 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 3- 3 3.1.1.3 O2 Content Sampling 1.

Strona 31

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 3 3- 4 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 Use air band and shutter set

Strona 32

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 3 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 3- 5 6. Once the Burner lights, sam

Strona 33

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 4 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 4- 1 4-1 MAINTENANCE The Pureheat™

Strona 35

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 4 4- 2 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 1. Burner Mounting Flange 2.

Strona 36

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 4 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 4- 3 4. Using the supplied 1¼ in.

Strona 37

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 4 4- 4 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 4.2.2.1 Installation (Refe

Strona 38

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 4 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 4- 5 4.3 HIGH ALTITUDE OPERATIONS 1

Strona 39

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 4 4- 6 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 4.5 SUMMER STORAGE INSTRUCTIO

Strona 40

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 5 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 5-1 12345678WARNINGFAILURE TO FOLL OW TH

Strona 41

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 6 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 6- 1 TROUBLESHOOTING 6.1 TROUBLESHO

Strona 42

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 6 6- 2 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 If problem is not resolved

Strona 43 - DIESEL FUEL SELECTION

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 6 V. 2, Rev. 09/01/06 © 2006 Ground Heaters, Inc. 6- 3 6-1 6.2 HTF LOW LEVEL FAULT A

Strona 44

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL – SECTION 6 6- 4 © 2006 Ground Heaters, Inc. V. 2, Rev. 09/01/06 6.3 BURNER CONTROL LOCKOUT (R

Strona 45 - HYDRONIC AIR HEATER

© 2006 Ground Heaters, Inc. i V. 2, Rev. 09/01/06 This Pureheat™ Hydronic Air Heater manual contains the following: 1. Pureheat™ Hyd

Strona 46

SCHEMATIC AND WIRING DIAGRAM SYMBOL LEGENDA – 1aPUSH BUTTON SWITCH, MOMENTARY, NORMALLY OPEN: A momentary push button switch that CLOSES on activation

Strona 47

SCHEMATIC AND WIRING DIAGRAM SYMBOL LEGENDWIRE JUMP: Used to show wires that are adjacent but are not connected to each other.CONNECTION POINT: Used

Strona 48

CAPACITOR: Used to add starting torque and efficiency to single phase electric motors. Capacitors are rated by Microfarad (µf or mfd) and volts i.e.:

Strona 49

PUREHEAT CONTROL PANEL EXTERIOR LAYOUTHOURSooLINE1GFIMAINBREAKER 1MAINBREAKER 2LINE 2 GFIWARNINGREFER TO OPERATORMANUALTO CLEARFAULTSCABLIGHTOFFONOFFH

Strona 50 - V. 2, Rev. 09/01/06

FFUJIELECTRICPXR-4C1 C2 AL1 AL3AL2SVPVSELPUREHEAT TEMPERATURE CONTROLA+ -DFUJI MODEL PXR-4BCEHEATING DEMAND INDICATORAPROCESS VALUE (HTF TEMPERATURE)B

Strona 51

L1L32, 21319914211815L31N12L426N217L2L41,19,9BLURED1,12221GGCAB LIGHTSW.HOSE REWIND SW.BURNER SW.PUMPSW.HTF FILLSW.1,15TEMPERATURECONTROLHOURSLINE 1 G

Strona 52 - IGN. TRANS

PUREHEAT MAIN CONTROL PANEL EXTERIOR COMPONENT FUNCTION AND IDENTIFICATIONDOOR COMPONENTSBREAKER 1 CURVE 10 15 AMP. (P/N E100-354):Provides ON and OFF

Strona 53 - ELECTRIC

18218224Jumper 26Jumper 2623T1BlankBlankBlankBlank6 78CR1842637CR2423CR3COILNCCOILCOM NO6CR42 311005422112019112 1122224 313 102926 1627RECTIFIER+~~-2

Strona 54

PANEL INTERIOR COMPONENTSCR-1 RELAY (P/N E100-205):Relay CR-1 is controlled by the Low Level Shutdown Device contacts C - B (NO) (normally open). Rela

Strona 55

FOOT SW.232424REDBLUPUMP SW.HTF FILL SW.19WHTWHTBLKBLKRED2526185 64 2101071599+120VACL1BLK11WHT22222WHTWHTWHT22CR-112VAC 7 8 11REWIND CLUTCH3.9A, 12V

Strona 56 - PUREHEAT MAIN CONTROL PANEL

© 2006 Ground Heaters, Inc. ii V. 2, Rev. 09/01/06 The licensed gas technician mu

Strona 57

PUREHEAT WIRING SCHEMATIC(SHEET 2)CIRCUIT 1 WITH DIESEL BURNERBURNER CABLEBURNER CABLENBURNER SW.221WHTBLKLOW LEVEL4ORGREDPIN-B (WHT)101313122TS13PIN-

Strona 58

BLKPUREHEAT SAFETY CONTROLSDIESEL BURNER WIRINGREDBLK213TTBLU/WHTWHTWHTL-2L-2L-2L-2L-1LIMITBURNERVALVEIGNALARMALARMC-C+CADCELLYELYELBURNER CONTROL(P/N

Strona 59 - CIRCUIT 1

BLUREDBURNER CABLEBURNER CABLENLOW LEVEL FAULT LAMP221WHTBLKHOUR METERLOW LEVEL4ORGREDPIN-B (WHT)10RECEPTACLE1313223PIN-E (ORG)PIN-F (RED)PIN-D (BLU)2

Strona 60 - (SHEET 2)

PUREHEAT DIESEL BURNER CONTROL SEQUENCE OF OPERATION AND LOCKOUTNORMAL SEQUENCE OF OPERATION:Assuming a normal power up has been completed per Section

Strona 61 - (P/N P100-206)

GAS BURNERCONTROLP/N P100-338A B C D E F GCOMNOCOILCOILPUREHEAT SAFETY CONTROLSNG/LP BURNER WIRING DIAGRAMl213141516171819202122GL2310F789456SEVEN PIN

Strona 62 - (SHEET 3)

PILOTFLAMEMAINALARMPOWERRESETHoneywellBURNER CONTROLSSHoneywellBURNER CONTROLFlame AmplifierReset Button: Press and release to clear Burner ALARM con

Strona 63

15 SECOND FLAME CHECK30 SECOND PRE-PURGE1-3 SECONDSPILOTFLAMEMAINALARMPOWERRESETBURNER SWITCH ONPILOTFLAMEMAINALARMPOWERRESETPILOT GAS VALVE POWEREDPI

Strona 64 - Honeywell

+120VACL2N2L4PUMP MOTOR 15.8A 1.5 HP1626171716PUMP262617BLK16BLK26BLK26BLKWHT17WHT1720ACB-2LINELOADLOW LEVELLOGICH NGFCI-2GROUND FAULT INDICATOR LAMPL

Strona 65 - © 2006 Ground Heaters, Inc

PUREHEAT SCHEMATIC – AUXILIARY PUMP PANEL(P/N A109-199) BOOSTER PUMP AND AUXILIARY PUMP PANEL INTERNAL SCHEMATICAuxiliaryPump PaneloAux. Pump CableOUT

Strona 66

PUREHEAT CIRCULATION - BOOSTER PUMP MOTOR WIRINGGNDCIRCULATION - BOOSTER PUMP ASSY.1.5 HP 15.8 FLA 18.8 SFAP/N M100-647PUMP CABLE16174 13YELBLUORGWHI

Strona 67 - CIRCUIT 2

© 2006 Ground Heaters, Inc. iii V. 2, Rev. 09/01/06 Operator Manual available in French language upon re

Strona 68 - (P/N A109-199)

PUREHEAT REWIND MOTOR WIRINGV. 2, Rev. 09/01/06A - 17© 2006 Ground Heaters, Inc.DAYTONGEAR MOTOR1/6thHP 120 v. 60 HzP/N E100-212CAPACITOR10 µƒ330VGND

Strona 69 - P/N M100-647

PUREHEAT SAFETY CONTROLS LOW LEVEL SHUTDOWN DEVICE(P/N E100-198)NOTE: CONTROL IS SHOWN IN A NON-POWERED STATEV. 2, Rev. 09/01/06A - 18© 2006 Ground H

Strona 70 - PUREHEAT REWIND MOTOR WIRING

HX200 HEAT XCHANGER™ WIRING DIAGRAMBLUE MEDIUMRED LOBLK HIBLOWER MOTORE100-349BRN BRN53124P/N E100-335THERMOSTATP/N M100-740P/N E100-334ROTARY SWITCHC

Strona 71 - HEATER SHELL

P/N E100-335THERMOSTATP/N M100-773TOGGLE SWITCHP/N E100-101CAPACITORRECESSED PLUGL-1 BLK T-1 YEL370V 7.5 mfdP/N M100-769BLK HIRED LOBLU MEDBLOWER MOTO

Strona 72 - RECESSED PLUG

P/N E100-335THERMOSTATP/N M100-773TOGGLE SWITCHP/N E100-101RECESSED PLUGWIRE COLORSBRN = BROWNBLK = BLACKRED = REDWHT = WHITEGRN = GREENBLU = BLUEL-1

Strona 73

PUREHEAT TRAILER JUNCTION BOX AND BATTERY WIRINGBLU = BLUE - BRAKESTRAILER WIRE COLORSBLK = BLACK - NOT USEDRED = RED - LEFT TURNWHT = WHITE - NEGATIV

Strona 74

PUREHEAT TRAILER WIRINGBATTERY WIRE COLORSBLK = BLACK - VEHICLE 12 VOLTS DCWHT = WHITE - NEGATIVE/GROUNDGRN = GREEN - TRAILER BATTERYRED = RED - L

Strona 75

PUREHEAT NG/LP BURNER COMPONENT IDENTIFICATION(P/N P100-673)HONEYWELLRESETPOWERFLAMEALARMPILOTMAINUVHPFGJQMKCEBDLNOIWRSATREGULATOR DUST CAPMANIFOLD GA

Strona 76 - ELECTRIC BRAKES

PUREHEAT NG/LP BURNER (P/N P100-673)GAS PRESSURE CHECKING AND ADJUSTINGRESETHONEYWELLPOWERFLAMEALARMPILOTMAINREMOVE THE PIPE PLUG AND CONNECT A 0-15&q

Strona 77

PUREHEAT DIESEL BURNER COMPONENT IDENTIFICATION(P/N P100-690)BECKETTCF 800FUEL PRESSURE ADJUSTING SCREWFUEL SYSTEM BLEEDER PORTFUEL PRESSURE TEST PORT

Strona 78

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’S MANUAL V. 2, Rev. 09/01/06 iv © 2006 Ground Heaters, Inc. TABLE OF CONTENTS Page Technical, Che

Strona 79 - INCREASE

SUGGESTED METHOD FOR SECURING THE PUREHEAT ONTO A TRUCK BEDV. 2, Rev. 09/01/06A - 27© 2006 Ground Heaters, Inc.00000000000000000000000000000000000000

Strona 80

BCDAFIHGEABCDEFGHIGEAR MOTOR (P/N E100-212)MOTOR SHAFT ADAPTER (P/N F102-026)KEY, ¼ X ¼ X 1¾ (P/N M100-730)RETAINING RING (P/N M100-707)BRAKE ASSEMBL

Strona 81

PUREHEAT AIR AND SURFACE HEATING ACCESSORIESHX200 Heat Xchanger™(P/N G109-005)BOOSTER PUMP(P/N G109-014)HHS 3004(P/N G302-009)(P/N G109-006)HX50 Heat

Strona 82 - Auxiliary

BOOSTER PUMP TO PUREHEAT CONNECTINGHTF SUPPLY - FLOW DIRECTIONHTF RETURN - FLOW DIRECTION1.ENSURE VALVES 5,6 AND 7 ARE SHUT.REMOVE THE CAPS AND PLUGS

Strona 83 - Aux. Pump Cable

HX200(P/N G109-005)HX200(P/N G109-005)HX200 HEAT XCHANGER™ TO PUREHEAT CONNECTION LAYOUTHX200(P/N G109-005)HX200(P/N G109-005)FRETURN MANIFOLD2OPENMA

Strona 84

SUPPLY MANIFOLDFILL HOSEFILL HOSE DUST CAPHX100 HEAT XCHANGER™ TO PUREHEAT CONNECTION LAYOUTFRETURN MANIFOLD2OPENMAINPUMPPSIPRESSUREGAUGECHECKVALVE576

Strona 85

HX50 HEAT XCHANGER TO PUREHEAT CONNECTION LAYOUTFRETURN MANIFOLD2OPENMAINPUMPPSIPRESSUREGAUGECHECKVALVE576SHUTOPENSHUT34SHUTOPENHTF SUPPLY - FLOW DIR

Strona 86

PUREHEAT 18,000 SQ. FT THAW LAYOUT (THREE HHS 3004'S AND THREE 4-PORT MANIFOLDS)FRETURN MANIFOLD2OPENMAINPUMPPSIPRESSUREGAUGECHECKVALVE576SHUT34

Strona 87

SUPPLY MANIFOLDFILL HOSEFILL HOSE DUST CAPPUREHEAT 30,000 SQ. FT CURE LAYOUT(FIVE HHS 3004'S AND FIVE 4-PORT MANIFOLDS) FRETURN MANIFOLD2OPENMAIN

Strona 88

PUREHEAT 45,000 SQ. FT FROST PREVENTION LAYOUT(FIVE HHS 3004'S AND FIVE 4-PORT MANIFOLDS) V. 2, Rev. 09/01/06B - 8© 2006 Ground Heaters, Inc.SUP

Strona 89

PUREHEAT™ HYDRONIC AIR HEATER OPERATOR’SMANUAL © 2006 Ground Heaters, Inc. v V. 2, Rev. 09/01/06 TABLE OF CONTENTS

Strona 90

1. Power up the PureHeat as described in section 2 of this manual.2. Place the container of HTF near the access doors for the Hose Reel and the Ma

Strona 91

PUREHEAT VALVE POSITIONS FOR ADDING HTF(Machine not in use)PSIPRESSUREGAUGEMAINPUMPCHECKVALVEFRETURN MANIFOLD5762SHUTOPENOPENSHUTSUPPLY MANIFOLD1. P

Strona 92

ALWAYS:Keep connection devices free of sand and dirt.Rinse in clear water before and after each use.Inspect seals and gaskets before and after each us

Strona 93 - HTF RETURN

PUREHEAT APPLICATIONS AND CAPACITIES(See Appendix pages B-1 – B-10 for accessories connecting)© 2006 Ground Heaters, Inc.V. 2, Rev. 09/01/06C - 1HTF

Strona 96 - Wacker

Wacker Construction Equipment AG · Preußenstraße 41 · D-80809 München · Tel.: +49-(0)89-3 54 02 - 0 · Fax:

Komentarze do niniejszej Instrukcji

Brak uwag