CRT 48-31V-ES Operation
wc_tx000143gb.fm 23
4.9 Status Indicator Lights
See Graphic: wc_gr001496
During normal operation, the green status indicator light will remain on.
A flashing green light indicates the software is operating in “limp home”
mode. This can occur if a load pin is damaged or has an open or short
circuit in the wire harness. The “limp home” mode is designed to allow
the operator to continue steering the trowel at a reduced level until a
repair can be made. The trowel is calibrated at the factory and should
not normally require calibrating. However, if a damaged load pin is
detected, calibration may be required. Calibration may be done by
contacting your local WACKER authorized service dealer.
The red status indicator light is used to flash error codes for
troubleshooting. See chart below for error codes (listed in priority) and
descriptions. The error code will continue to flash until the error is
corrected. Multiple errors will flash in order of priority. After the first
error is corrected the second error will flash and so on, until all errors
are corrected.
Ref. Description Ref. Description
111 Right control fault 231 Left load pin open circuit
121 Side control fault 232 Left load pin short circuit
131 Left control fault 311 Right joystick open circuit
211 Right load pin open circuit 312 Right joystick short circuit
212 Right load pin short circuit 321 Left joystick open circuit
213 Right load pin bent 322 Left joystick short circuit
221 Side load pin open circuit 414 Control board over temperature
(above 80° C / 176° F)
222 Side load pin short circuit 415 Low battery voltage
223 Side load pin bent